BUGASS · BRU SERIES
U-Tube Radiant Heater
Powerful, even and efficient heating for high-ceilinged buildings.
With its U-tube design, the Bugass BRU Series spreads heat evenly across a wide area. It offers a controlled, comfortable solution tailored to each project, for general and zoned heating in factories, warehouses, hangars and production areas.
- Output range
- 15–55 kW
- Fuel
- Natural gas / LPG
- Heating type
- U-tube radiant
OVERVIEW
Even, efficient heating comfort with the BRU Series
Bugass BRU Series U-tube radiant heaters deliver effective heating in large, high-ceilinged spaces such as factories, warehouses, sports halls, hangars, supermarkets and exhibition halls. The U-tube design spreads heat evenly across a wide area.
Heat generated in the burner travels in a controlled way along parallel radiant tubes and reaches people, floors and surrounding surfaces directly as infrared radiation. Instead of heating all of the air, it targets the points that need warmth.
The Bugass BRU Series is a powerful, efficient and reliable solution for general area heating as well as zoned and spot applications.
BUGASS BRU · PRODUCT ADVANTAGES
Performance, efficiency and control
The key advantages that make the Bugass BRU Series a strong choice for industrial projects.
- Even U-Tube Heating The U-tube design distributes heat evenly across a wide area. 01
- Models to Suit Every Project Output options from 15 to 55 kW to match different spaces and capacity needs. 02
- Three-Stage Control Three output stages give quick, easy access to operating settings. 03
- Industrial Durability A robust, reliable and long-lasting system built for demanding operating conditions. 04
ENGINEERING DETAILS
Verified technical performance of the BRU Series
Output, consumption and installation data for models BRU15–BRU55.
-
01
Three-stage operation
Three output stages on every model, with a 10–55 kW capacity range across the series.
-
02
Nine models
From BRU15 to BRU55, with overall lengths from 3,720 to 9,720 mm.
-
03
Natural gas or LPG
Consumption of 1.00–5.73 Nm³/h on natural gas and 0.78–4.28 kg/h on LPG.
-
04
Safe installation, planned for the project
Fully automatic ignition with flame sensor; recommended mounting height 2.00–4.00 m.
Applications
High efficiency in the right setting
The right model is chosen based on the ceiling height, usage pattern and heat demand of each project.
-
Factories
-
Warehouses
-
Sports halls
- Hangars
- Supermarkets
- Exhibition halls
Technical Specifications · BRU Series
Scroll the table horizontally to see all BRU models
| Model | BRU15 | BRU20 | BRU25 | BRU30 | BRU35 | BRU40 | BRU45 | BRU50 | BRU55 | |
|---|---|---|---|---|---|---|---|---|---|---|
| Output (kW) | Stage 1 | 10 | 13 | 16 | 19 | 22 | 25 | 29 | 32 | 35 |
| Stage 2 | 12 | 16 | 20 | 25 | 29 | 33 | 37 | 41 | 45 | |
| Stage 3 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | |
| Dimensions & Installation Data · BRU Series | ||||||||||
| Weight (kg) | 44 | 59 | 59 | 74 | 74 | 74 | 89 | 89 | 104 | |
| Overall length (mm) | 3720 | 5220 | 5220 | 6720 | 6720 | 6720 | 8220 | 8220 | 9720 | |
| Min. recommended mounting height (m) | 2 | 2.25 | 2.5 | 2.75 | 3 | 3.25 | 3.5 | 3.75 | 4 | |
| Fuel Consumption & Connections · BRU Series | ||||||||||
| Gas type | Natural gas or LPG | |||||||||
| Natural gas consumption (Nm³/h) | Stage 1 | 1.00 | 1.33 | 1.66 | 1.99 | 2.32 | 2.65 | 2.98 | 3.31 | 3.64 |
| Stage 2 | 1.28 | 1.71 | 2.13 | 2.56 | 2.98 | 3.41 | 3.83 | 4.26 | 4.68 | |
| Stage 3 | 1.57 | 2.09 | 2.61 | 3.13 | 3.65 | 4.17 | 4.69 | 5.21 | 5.73 | |
| LPG consumption (kg/h) | Stage 1 | 0.78 | 1.04 | 1.3 | 1.57 | 1.83 | 2.09 | 2.35 | 2.62 | 2.88 |
| Stage 2 | 0.96 | 1.28 | 1.61 | 1.93 | 2.25 | 2.57 | 2.9 | 3.22 | 3.54 | |
| Stage 3 | 1.16 | 1.55 | 1.94 | 2.33 | 2.72 | 3.11 | 3.5 | 3.89 | 4.28 | |
| Inlet pressure (mbar) · Natural gas | 15 min. – 55 max. | |||||||||
| Inlet pressure (mbar) · LPG | 15 min. – 55 max. | |||||||||
| Gas connection | 3/4" threaded | |||||||||
| Electrical connection | 230 V, single-phase, 1 A | |||||||||
| Fan power (W) | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |
| Ignition | Fully automatic, with flame sensor | |||||||||
| Combustion & radiant tubes | 101.6 mm diameter heat-treated aluminized steel tube | |||||||||
| Reflector | NS3H14 aluminum | |||||||||
| Flue outlet diameter (mm) | 101.6 | |||||||||
| Installation & Safety Clearances · BRU Series | ||||||||||
| Minimum clearances to combustibles (cm) | Above | 15 | 15 | 15 | 15 | 15 | 15 | 20 | 20 | 20 |
| Sides | 75 | 80 | 85 | 90 | 95 | 100 | 110 | 120 | 130 | |
| Below | 150 | 160 | 170 | 170 | 170 | 170 | 200 | 200 | 220 | |
Engineering Support
Let's size the BRU Series for your project.
Together we'll review ceiling height, usage pattern and operating conditions to select the right system.
Tell Us About Your Project
Technical documents
Files for your project
Published documents open directly; for any missing document, request it from our technical team, stating the product series.
Data sheet Available on request
Installation & user manual Available on request
Product catalog Available on request
System selection for your project