BS Series
Ceramic Radiant Heater
BUGASS BS Series ceramic radiant heaters come with remote control and a three-stage heat setting. They provide comfortable, fast and targeted heating in open and semi-open spaces.
- Output range
- 8–18 kW
- Fuel
- Natural gas / LPG
- Efficiency
- 3 stages
- Control
- 3-Stage Control
Overview
Controlled, reliable heating with the BS Series
BUGASS BS Series ceramic radiant heaters come with remote control and a three-stage heat setting. They provide fast, targeted heating in open and semi-open spaces.
Ceramic radiant technology directs heat to where it is needed, while 8, 12 and 18 kW output options suit projects of different sizes.
Product advantages
Performance, durability and control
Core product features developed for real project conditions.
- Remote Operation Easy access to heat stages with remote control. 01
- Three Heat Stages Three operating stages to match heat demand. 02
- Ceramic Radiant Technology A ceramic surface that delivers fast, targeted heat. 03
- Built for Open Areas Designed for open and semi-open spaces. 04
ENGINEERING DETAILS
Advanced engineering of the BS Series
Verified product data and project-focused engineering details.
-
01
8–18 kW output options
Three verified output options with the BS-4, BS-6 and BS-10 models.
-
02
Quiet operation
Quiet operation suited to comfort areas.
-
03
2.2–3 m mounting height
Mounting height range verified for each model.
-
04
Open ceramic surface (no glass)
A radiant operating principle that directs heat straight to where it is needed.
Applications
High efficiency in the right setting
The right model is chosen based on the ceiling height, usage pattern and heat demand of each project.
-
Open areas
-
Semi-open areas
-
Cafés and restaurants
- Terraces
- Commercial premises
Technical specifications
BS Series model comparison
Scroll the table horizontally to compare all models.
Scroll the table horizontally to see all BS models
| Product code | BS-4 | BS-6 | BS-10 | |
|---|---|---|---|---|
| Output (kW) | Stage 1 | 6 | 8 | 12 |
| Stage 2 | 7 | 10 | 15 | |
| Stage 3 | 8 | 12 | 18 | |
| Heating area* (m²) | 11–34 | 26–55 | 39–82 | |
| Natural gas consumption (m³/h) | Stage 1 | 0.63 | 0.84 | 1.26 |
| Stage 2 | 0.73 | 1.05 | 1.58 | |
| Stage 3 | 0.84 | 1.26 | 1.89 | |
| Recommended mounting height (m) | 2.0 | 2.2 | 2.5 | |
| Natural gas inlet pressure (mbar) | 18–55 | 18–55 | 18–55 | |
* Heating area values may vary with indoor or outdoor use, wind exposure, insulation, ceiling height and local climate.
Engineering Support
Let's size the BS Series for your project.
Together we'll review ceiling height, usage pattern and operating conditions to select the right system.
Tell Us About Your Project
Technical documents
Files for your project
Published documents open directly; for any missing document, request it from our technical team, stating the product series.
Data sheet Available on request
Installation & user manual Available on request
Product catalog Available on request
System selection for your project